Feature:
1.Combine with solar power controller and inverter hybrid function, with AGM free maintenance battery build-in.
2.Completely controlled by CPU.
3.Inverter use copper transformer, pure sine wave output.
4.Two LCD displays, clearly to know the status.
5.have bypass function and AC charger (UPS function)
6.Perfect protection. Protect against anti-charge at night, battery over charger/over discharge, output short-circuit, against overload, against over-voltage, over-current protection ,etc.
This inverter with controller and battery inside.
Products can be design base on the customer's need!
Solar controller is from 10A to 100A
Solar inverter is from 200W to 10KW.
Battery capacity is from 7AH to 200AH.
Pls contact the TradeManager to know more details!
Model: | SCB500 | SCB1000 | ||
Rated power(W) | 500W | 1000W | ||
Rated DC voltage(V) | 12V | 24V | ||
Line input | Input voltage(V) | 165-275V | ||
Charge current(A) | 20A | 40A | ||
Inverter output | Output voltage(V) | 220VAC±5% | ||
Output frequency | 50Hz/60Hz±1% | |||
Wave form | Pure Sine Wave,THD<4%(Full Load) | |||
Solar input | Maximum voltage((V) | 21 | 42 | |
Rated power(Wp) | 500 | 1000 | ||
Charge current(A) | 20 | 40 | ||
MPPT range(V) | 12v-17v | 24v-34v | ||
Charging efficiency | 90%-95%, Peak on 97% | |||
Battery | Capacity(AH) | 65AH*1pcs | 100AH*2pcs | |
Over charge protective voltage(V) | 14.3 | 28.6 | ||
Over charge recover voltage(V) | 13.7 | 27.4 | ||
Over discharge alarm voltage(V) | 20 | 40 | ||
Over discharge recover voltage of battery(V) | 12.5 | 25 | ||
other | Voltage drop between solar module and battery(V) | ≤0.3V | ||
Voltage drop between loads and battery(V) | ≤0.15V | |||
Start speed of cooling fan | Have | |||
Environment Humidity | 0-90% Maximum,non-condensable | |||
Protective Functions | Protection against anti-charge at night;Battery over charge/ over discharge protection; Joint-reversed of solar modules | |||
Control method | MPPT | |||
Size :D*W*H(mm) | 415*198*485 | 415*322*655 | ||
N.W./G.W.(kg) | 45/48 | 85/95 |